Heat Transfer Unit (Oil Heater)
Heat Transfer Unit is used to heat the asphalt tanks, mix plants and storage silos that supply materials to main source. The hot asphalt is pumped into liquid storage tanks and sent through piping system to the weigh scale. Here is mix with aggregate which had been previously heated to 340F to remove any residual water. The mixed asphalt is then moved to storage silos, where it waits to be loaded into trucks for jobsite delivery. If there is bad weather like rain and screws cannot work, the heat transfer fluid has to keep the asphalt hot at the plant for up to week or more. Capacities of Heat Transfer Unit: Maximum BTU input light oil 255,500 (2.5million) Burner with complete safety system High temperature insulation helps to protect the loss of the heat Inside 2” seamless coil for oil Hot oil circulation pumps 60m3/h Made in Italy with usa motor. Pressure & Temperature Complete Automatic Electrical panel to control the pressure and temperature complete automatic Level indication system 145 Gal. oil required to charge the heater for smooth operation.